Magnetic Switch and Relay Circuit
The circuit is pretty basic. A magnetic switch is mounted underneath the shifter.
The magnet is mounted on the shifter arm. When the shifter is directly over the
magnetic switch (neutral position) there is continuity between the terminals of the
magnetic switch. Any other position besides neutral results in an open circuit at
the magnetic switch. The magnetic switch is connected to a SPDT relay so that
when the switch is closed (neutral), the relay coil is energized by ignition voltage
and the common output (pin 30) is connected to an open circuit (pin 87). If the
car is in any gear, the relay coil is not energized and the common output (pin 30)
is connected to ground (pin 87a). If there is a diode connected across the relay
coil REMOVE IT to avoid ground noise that could trigger your Remote Top
Interface circuits.
The common terminal (pin 30) is connected to the stock Theft Alarm Relay at
connector C56-3 (G-B wire). When this wire is grounded, the Starter Relay is
disabled.
Figure 4 - Neutral Safety Circuit
Make sure the Ground connections in this circuit are FIRMLY attached to the
bare metal of the center console. It is best to select a different location than the
one you used for the Remote Top Interface Module ground.